<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>101</ErrorNumber>
<ErrorFamily>Miscellaneous</ErrorFamily>
<ErrorMessage>
MISC: LCA module checksum is faulty
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
An LCA file currently stored in the code banks (i.e. Flash memory) is corrupt.  The "fw dir" command can
be used to determine which LCA file(s) are corrupt.  Look under the "Chksum" column for the entries that
"FAIL".  The corresponding LCA(s) will not be loaded on startup.  The code bank must be programmed
again.
</text></DescriptionText>
<DescriptionText><text>
If this error is reported again and the last LCA file(s) in the directory are the corrupt one(s), the code bank
may be too small for the downloaded file.  Check with a firmware programmer.  The Flash parts on the
MPE may also be faulty, so try a new MPE.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
The firmware in the code bank was somehow corrupted
</Cause>
<Cause>
The MPE's Flash parts are faulty
</Cause>
<Cause>
The MPE's code bank is too small for the downloaded file
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/fw_dir.xml</LinkAddress><LinkTitle>Command: fw dir</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:16 2008 PST
</Updated>
<Links>
</Links>
</Error>